جهاز الصدمات الكهربائى (مزيل الرجفان الخارجى الالى) مناسب لحالات البالغين و الاطفال.
الجهاز مزود بخاصية AED (مزيل الرجفان الخارجى الالى).
امكانية اختيار مدى طاقة الصدمة الكهربائية بداية من 50 جول حتى 200 جول.
الجهاز مزود بمكبر صوت ذو جودة عالية، و مهمته اصدار التعليمات الصوتية بصوت عال و جودة عالية و صوت نقي و مسموع، مما يسهل على المستخدم الاستماع الى التوجيهات و ذلك لسهولة الاستخدام.
الجهاز مزود بازرار مضادة لتسرب المياه و السوائل و ناعمة الملمس و ذو جودة عالية.
Two languages to choose from (by end user)
Five volume levels (by the end user)
Button for adult/child mode
Infrared for data transmission (standard)
Daily, weekly and monthly self-test
Use of AED in pocket (does not need to be opened)
Extra pocket in the bag for first aid products
IPX55 water and dust resistant
Selectable energy for patients of different ages
50. 50. 75J
150. 150. 200J
Comprehensive voice and visual prompts for the operator
Manually switchable language
Biphasic energy delivery
Interlock protection to prevent accidental defibrillation
Device has internal memory (60 hours)
ECG signals and events can be transferred to computer
Comes with carrying case, battery and pad,
It has a long life disposable LiMnO2 type battery (battery life at least 5 years)
AED storage software (standard configration)
Used to support the upper monitoring system of the DEFI® automated external defibrillator
Data communication
DefiSoft AED software supports receiving data sent via infrared,
Reading and setting ECG waves, setting Defi®5s S language, reading, analyzing and saving data can also be done with Meditech Defi®5s S Memory software.
Case management
DefiSoft converts the selected data file into a case record and stores cases in the database ACCESS.
Case management supports importing and deleting data and can respond to the ECG waveform of the file by selecting cases.
3 Memory playback
The interfaces display status information recorded during the operation of the
Defi®5s S recorded status information, including type, event time, description, and waves.
Event type includes: On event, Self test event, Analysis event, Charge event, Discharge event, CPR start event, CPR stop event. Event time displayed indicates when the event occurred. Description displays the parameter information. “OHM” displays the detected impedance of the patient. The parameter “Power” indicates the voltage of the completed charge; “Shock required” indicates that a shock is recommended after the analysis; “No shock required” indicates that no shock is recommended after the analysis.
ECG
Waveform gain can be set to 5mm/mv, 10mm/mv, 20mm/mv; waveform speed can be set to 12.5mm/s, 25mm/s, 50mm/s:
Print
Displays a preview of the selected page and prints basic information